TECO IE2 Flameproof (Exd/Exde)

TECO IE2 Flameproof (Exd/Exde)

Superior Performance and Safety in Hazardous Environment, IEC Ex and ATEX, IP56 Protection TECO IE2 Flameproof Electric Motor has been certified with IEC Ex and ATEX certifications, ensuring its compliance read more…

  • IEC Ex and ATEX Certified with certification available as :
  • Ex d (Flameproof Motor and Terminal Box) , Zone 1/Zone 2 , IIB , T4(T3*) , 50 deg C ambient
  • Ex de (Flameproof Motor with Increased Safety Terminal Box) , Zone 1/Zone 2 , IIC , T4 (T3*) , 50 deg C ambient
  • *T3 for converter supply (PWM Converter , Inverter) . Condition of safe use is mandatory connection of thermistors.
  • Metric frame motors to AS1359, AS/BS frame allocation
  • D80 to D280 frames
  • 0.55 kW to 55 kW (Stock) or 110kW (Built to Order)
  • Totally Enclosed Fan Cooled (IC411)
  • Motor type AEHBXZ , meets or exceeds AS1359.5 Minimum Efficiency Performance Standard, table B2 (a number of motors meet or exceed high efficiency to table B3)
  • 380~415 Volts 3 Phase 50 Hz (other supplies on request)
  • Class F insulation system materials
  • Low temperature rise for substantial thermal reserve
  • Continuous rated, duty type S1
  • Low noise level
  • IP55 protection
  • Motors available painted R13 red (AS2700) off the shelf.
  • Cast Iron construction with side mounted terminal box
  • Mountings available – Foot, Foot and flange (D type only), Flange (D type only)
  • MAX Ex Brake Motors
  • 2 year warranty​
  • Ensures compliance with safety standards and regulations
  • Reliable motors designed for hazardous environments
  • Versatile options for different installation requirements
  • Can operate in challenging conditions with IIB or IIC group ratings
  • Offers a wide range of power outputs to meet various needs
  • Effective heat dissipation and protection for extended motor life
  • Energy-efficient motors that exceed minimum performance standards
  • Compatible with standard power supply or adaptable to specific requirements
  • Durable construction materials for long-lasting performance
  • Flexible mounting options to accommodate different setups
  • Suitable for continuous operation without overheating
  • Provides a quieter working environment for improved comfort
  • Protection against dust and water to ensure motor reliability

No software downloads.

Download Drawings

Listing can be filtered by using the Motor Selector

Frame Size PDF Drawings CAD Drawings 3D Drawings
80 PDF Drawing CAD Drawing
90L PDF Drawing CAD Drawing
90S PDF Drawing CAD Drawing
100L PDF Drawing CAD Drawing
112M PDF Drawing CAD Drawing
132M PDF Drawing CAD Drawing
132S PDF Drawing CAD Drawing
160L PDF Drawing CAD Drawing
160M PDF Drawing CAD Drawing
180LC PDF Drawing CAD Drawing
180MA PDF Drawing CAD Drawing
180MC PDF Drawing CAD Drawing
200LA PDF Drawing
225MA PDF Drawing

Download Datasheets

Listing can be filtered by using the Motor Selector

KW Rating Voltage Phases No of Poles Frame Datasheet PDF
0.75 415 3 2 80 Datasheet PDF
0.75 415 3 4 80 Datasheet PDF
0.75 415 3 6 90S Datasheet PDF
1.1 415 3 2 80 Datasheet PDF
1.1 415 3 4 90S Datasheet PDF
1.1 415 3 6 90L Datasheet PDF
1.5 415 3 2 90S Datasheet PDF
1.5 415 3 4 90L Datasheet PDF
1.5 415 3 6 100L Datasheet PDF
2.2 415 3 2 90L Datasheet PDF
2.2 415 3 4 100L Datasheet PDF
2.2 415 3 6 112M Datasheet PDF
3 415 3 2 100L Datasheet PDF
3 415 3 4 100L Datasheet PDF
3 415 3 6 132S Datasheet PDF
4 415 3 2 112M Datasheet PDF
4 415 3 4 112M Datasheet PDF
4 415 3 6 132M Datasheet PDF
5.5 415 3 2 132S Datasheet PDF
5.5 415 3 4 132S Datasheet PDF
5.5 415 3 6 132M Datasheet PDF
7.5 415 3 2 132S Datasheet PDF
7.5 415 3 4 132M Datasheet PDF
7.5 415 3 6 160M Datasheet PDF
11 415 3 2 160M Datasheet PDF
11 415 3 4 160M Datasheet PDF
11 415 3 6 160L Datasheet PDF
15 415 3 2 160M Datasheet PDF
15 415 3 4 160L Datasheet PDF
15 415 3 6 180LC Datasheet PDF
18.5 415 3 2 160L Datasheet PDF
18.5 415 3 4 180MC Datasheet PDF
18.5 415 3 6 200LC Datasheet PDF
22 415 3 2 180MA Datasheet PDF
22 415 3 4 180LC Datasheet PDF
22 415 3 6 200LC Datasheet PDF
30 415 3 2 200LA Datasheet PDF
30 415 3 4 200LC Datasheet PDF
30 415 3 6 225MC Datasheet PDF
37 415 3 2 200LA Datasheet PDF
37 415 3 4 225SC Datasheet PDF
45 415 3 2 225MA Datasheet PDF
55 380/660 3 4 250SC Datasheet PDF

Features

  • IEC Ex and ATEX Certified with certification available as :
  • Ex d (Flameproof Motor and Terminal Box) , Zone 1/Zone 2 , IIB , T4(T3*) , 50 deg C ambient
  • Ex de (Flameproof Motor with Increased Safety Terminal Box) , Zone 1/Zone 2 , IIC , T4 (T3*) , 50 deg C ambient
  • *T3 for converter supply (PWM Converter , Inverter) . Condition of safe use is mandatory connection of thermistors.
  • Metric frame motors to AS1359, AS/BS frame allocation
  • D80 to D280 frames
  • 0.55 kW to 55 kW (Stock) or 110kW (Built to Order)
  • Totally Enclosed Fan Cooled (IC411)
  • Motor type AEHBXZ , meets or exceeds AS1359.5 Minimum Efficiency Performance Standard, table B2 (a number of motors meet or exceed high efficiency to table B3)
  • 380~415 Volts 3 Phase 50 Hz (other supplies on request)
  • Class F insulation system materials
  • Low temperature rise for substantial thermal reserve
  • Continuous rated, duty type S1
  • Low noise level
  • IP55 protection
  • Motors available painted R13 red (AS2700) off the shelf.
  • Cast Iron construction with side mounted terminal box
  • Mountings available – Foot, Foot and flange (D type only), Flange (D type only)
  • MAX Ex Brake Motors
  • 2 year warranty​

Benefits

  • Ensures compliance with safety standards and regulations
  • Reliable motors designed for hazardous environments
  • Versatile options for different installation requirements
  • Can operate in challenging conditions with IIB or IIC group ratings
  • Offers a wide range of power outputs to meet various needs
  • Effective heat dissipation and protection for extended motor life
  • Energy-efficient motors that exceed minimum performance standards
  • Compatible with standard power supply or adaptable to specific requirements
  • Durable construction materials for long-lasting performance
  • Flexible mounting options to accommodate different setups
  • Suitable for continuous operation without overheating
  • Provides a quieter working environment for improved comfort
  • Protection against dust and water to ensure motor reliability

Software

No software downloads.

Data Sheet

Download Datasheets

Listing can be filtered by using the Motor Selector

KW Rating Voltage Phases No of Poles Frame Datasheet PDF
0.75 415 3 2 80 Datasheet PDF
0.75 415 3 4 80 Datasheet PDF
0.75 415 3 6 90S Datasheet PDF
1.1 415 3 2 80 Datasheet PDF
1.1 415 3 4 90S Datasheet PDF
1.1 415 3 6 90L Datasheet PDF
1.5 415 3 2 90S Datasheet PDF
1.5 415 3 4 90L Datasheet PDF
1.5 415 3 6 100L Datasheet PDF
2.2 415 3 2 90L Datasheet PDF
2.2 415 3 4 100L Datasheet PDF
2.2 415 3 6 112M Datasheet PDF
3 415 3 2 100L Datasheet PDF
3 415 3 4 100L Datasheet PDF
3 415 3 6 132S Datasheet PDF
4 415 3 2 112M Datasheet PDF
4 415 3 4 112M Datasheet PDF
4 415 3 6 132M Datasheet PDF
5.5 415 3 2 132S Datasheet PDF
5.5 415 3 4 132S Datasheet PDF
5.5 415 3 6 132M Datasheet PDF
7.5 415 3 2 132S Datasheet PDF
7.5 415 3 4 132M Datasheet PDF
7.5 415 3 6 160M Datasheet PDF
11 415 3 2 160M Datasheet PDF
11 415 3 4 160M Datasheet PDF
11 415 3 6 160L Datasheet PDF
15 415 3 2 160M Datasheet PDF
15 415 3 4 160L Datasheet PDF
15 415 3 6 180LC Datasheet PDF
18.5 415 3 2 160L Datasheet PDF
18.5 415 3 4 180MC Datasheet PDF
18.5 415 3 6 200LC Datasheet PDF
22 415 3 2 180MA Datasheet PDF
22 415 3 4 180LC Datasheet PDF
22 415 3 6 200LC Datasheet PDF
30 415 3 2 200LA Datasheet PDF
30 415 3 4 200LC Datasheet PDF
30 415 3 6 225MC Datasheet PDF
37 415 3 2 200LA Datasheet PDF
37 415 3 4 225SC Datasheet PDF
45 415 3 2 225MA Datasheet PDF
55 380/660 3 4 250SC Datasheet PDF
Book a Consultation
Have questions or need assistance? Reach out to us through the contact form, and we’ll be happy to assist you.
This field is for validation purposes and should be left unchanged.