TECO Squirrel Cage

TECO Squirrel Cage

TECO Squirrel Cage Motors are custom designed to each customer’s specific application. Because of their design versatility and high operating efficiencies, TECO motors are the logical choice for a multitude read more…

Product Overview
Output 300 up to 15,000kW
Number of Poles: 2 to 12
Cooling method: TEAAC & TEFC
Degree of Protection: IP54 to IP66
Frames: 315 up to 1250
Ambient temperature: 40 °C
Elevation: 1000m above sea level
Service factor: 1.0 @ 40 deg C ambient
Mounting: IM1001
Voltages: Up to 13,800V
Insulation Class: “F” insulation (ΔT = 80K)
Continuous duty: S1
Design: N
Thermal protection: As per customer specification
Bearings: Anti-friction Bearings , Sleeve bearings
Frame Material: Fabricated Steeel
Color: As per customer specification
Options Available
Altitude above 1000 m (on request)
Aluminum, copper or brass rotor
Ambient temperature above 40 °C
Base: rail, sliding base, extended feet, rebuilt feet, anchorage plate
Bearing thermometer with gauge with/without contacts
Cable gland in the terminal box entrance
Class of insulation: H
Classified area application: Ex-n, Ex-p
Cooling: Forced ventilated, Air-to-water heat exchanger
CT for differential and integral protection
Electrically insulated bearing
Encoder
Grounding brush on drive end bearing
Independent hydraulic oil circulation system for sleeve bearing
Mountings: Vertical, Horizontal, Foot and Flange, Flange, NEMA Standard
Noise suppressor in the air inlet and outlet
Non-reversion ratchet
Multiple accessory terminal boxes
Power factor correction capacitors
Protection against voltage surge: Lighting arrestors and Capacitors
Service Factor: 1.15
Shaft: Special dimensions, double shaft end, tapered, hollow, special steel
Signal transducer
Sleeve bearing
Special balance
Special bearing (overdesigned) for axial or radial thrust
Special painting
Steel welded terminal box in different sizes, based on internal available space
Temperature detector: Thermistor (PTC or NTC)
Temperature detector: Thermostat (Bimetallic)
Two energized power terminal boxes
VFD application
Vibration detector

No software downloads.

Download Drawings
No Drawings available
Download Datasheets
Listing can be filtered by using the Motor Selector
KW Rating Voltage Phases No of Poles Frame Datasheet PDF
220 3300 3 2 315CA Datasheet PDF
220 3300 3 4 315CB Datasheet PDF
220 3300 3 6 315DB Datasheet PDF
220 3300 3 8 355CB Datasheet PDF
250 3300 3 2 315DA Datasheet PDF
250 3300 3 4 315DB Datasheet PDF
250 3300 3 6 315DB Datasheet PDF
260 3300 3 8 355CB Datasheet PDF
280 3300 3 2 315DA Datasheet PDF
280 3300 3 4 315DB Datasheet PDF
280 3300 3 6 315DB Datasheet PDF
300 3300 3 4 315DB Datasheet PDF
300 3300 3 8 355CB Datasheet PDF
315 3300 3 2 315DA Datasheet PDF
315 3300 3 6 355CB Datasheet PDF
315 3300 3 8 355DB* Datasheet PDF
340 3300 3 4 315DB Datasheet PDF
355 3300 3 2 355CA Datasheet PDF
355 3300 3 4 355CB Datasheet PDF
355 3300 3 6 355CB Datasheet PDF
355 3300 3 8 355DB* Datasheet PDF
375 3300 3 8 355DB Datasheet PDF
400 3300 3 2 355CA Datasheet PDF
400 3300 3 4 355CB Datasheet PDF
400 3300 3 6 355DB* Datasheet PDF
400 3300 3 8 400CB Datasheet PDF
425 3300 3 6 355DB* Datasheet PDF
450 3300 3 2 355CA Datasheet PDF
450 3300 3 4 355CB Datasheet PDF
450 3300 3 8 400DB* Datasheet PDF
475 3300 3 4 355DB* Datasheet PDF
475 3300 3 6 400CB Datasheet PDF
500 3300 3 2 355DA* Datasheet PDF
500 3300 3 4 355DB* Datasheet PDF
500 3300 3 6 400DB* Datasheet PDF
500 3300 3 8 400DB* Datasheet PDF
530 3300 3 2 400DA* Datasheet PDF
530 3300 3 8 450CB Datasheet PDF
560 3300 3 4 400CB Datasheet PDF
560 3300 3 6 400DB* Datasheet PDF
600 3300 3 2 400DA* Datasheet PDF
600 3300 3 6 400DB* Datasheet PDF
600 3300 3 8 450CB Datasheet PDF
630 3300 3 4 400CB Datasheet PDF
630 3300 3 6 450CB Datasheet PDF
650 3300 3 2 400DA* Datasheet PDF
650 3300 3 4 400DB* Datasheet PDF
650 3300 3 8 450DB* Datasheet PDF
670 3300 3 6 450CB Datasheet PDF
710 3300 3 2 400DA* Datasheet PDF
710 3300 3 4 400DB* Datasheet PDF
710 3300 3 8 450DB* Datasheet PDF
750 3300 3 2 450DA*-R Datasheet PDF
750 3300 3 4 400DB* Datasheet PDF
750 3300 3 6 450CB Datasheet PDF
800 3300 3 2 450DA*-R Datasheet PDF
800 3300 3 4 400DB* Datasheet PDF
800 3300 3 6 450CB Datasheet PDF
800 3300 3 8 500CB Datasheet PDF
850 3300 3 4 450CB Datasheet PDF
850 3300 3 6 450DB* Datasheet PDF
850 3300 3 8 500CB Datasheet PDF
900 3300 3 2 450DA*-R Datasheet PDF
900 3300 3 4 450CB Datasheet PDF
900 3300 3 6 500CB Datasheet PDF
930 3300 3 2 450DA*-R Datasheet PDF
930 3300 3 4 450DB* Datasheet PDF
930 3300 3 6 500CB Datasheet PDF
930 3300 3 8 500CB Datasheet PDF
1000 3300 3 2 450DA*-R Datasheet PDF
1000 3300 3 4 450DB* Datasheet PDF
1000 3300 3 6 500CB Datasheet PDF
1000 3300 3 8 500DB* Datasheet PDF

Product Overview

Product Overview
Output 300 up to 15,000kW
Number of Poles: 2 to 12
Cooling method: TEAAC & TEFC
Degree of Protection: IP54 to IP66
Frames: 315 up to 1250
Ambient temperature: 40 °C
Elevation: 1000m above sea level
Service factor: 1.0 @ 40 deg C ambient
Mounting: IM1001
Voltages: Up to 13,800V
Insulation Class: “F” insulation (ΔT = 80K)
Continuous duty: S1
Design: N
Thermal protection: As per customer specification
Bearings: Anti-friction Bearings , Sleeve bearings
Frame Material: Fabricated Steeel
Color: As per customer specification

Options Available

Options Available
Altitude above 1000 m (on request)
Aluminum, copper or brass rotor
Ambient temperature above 40 °C
Base: rail, sliding base, extended feet, rebuilt feet, anchorage plate
Bearing thermometer with gauge with/without contacts
Cable gland in the terminal box entrance
Class of insulation: H
Classified area application: Ex-n, Ex-p
Cooling: Forced ventilated, Air-to-water heat exchanger
CT for differential and integral protection
Electrically insulated bearing
Encoder
Grounding brush on drive end bearing
Independent hydraulic oil circulation system for sleeve bearing
Mountings: Vertical, Horizontal, Foot and Flange, Flange, NEMA Standard
Noise suppressor in the air inlet and outlet
Non-reversion ratchet
Multiple accessory terminal boxes
Power factor correction capacitors
Protection against voltage surge: Lighting arrestors and Capacitors
Service Factor: 1.15
Shaft: Special dimensions, double shaft end, tapered, hollow, special steel
Signal transducer
Sleeve bearing
Special balance
Special bearing (overdesigned) for axial or radial thrust
Special painting
Steel welded terminal box in different sizes, based on internal available space
Temperature detector: Thermistor (PTC or NTC)
Temperature detector: Thermostat (Bimetallic)
Two energized power terminal boxes
VFD application
Vibration detector

Software

No software downloads.

Drawings

Download Drawings
No Drawings available

Data Sheet

Download Datasheets
Listing can be filtered by using the Motor Selector
KW Rating Voltage Phases No of Poles Frame Datasheet PDF
220 3300 3 2 315CA Datasheet PDF
220 3300 3 4 315CB Datasheet PDF
220 3300 3 6 315DB Datasheet PDF
220 3300 3 8 355CB Datasheet PDF
250 3300 3 2 315DA Datasheet PDF
250 3300 3 4 315DB Datasheet PDF
250 3300 3 6 315DB Datasheet PDF
260 3300 3 8 355CB Datasheet PDF
280 3300 3 2 315DA Datasheet PDF
280 3300 3 4 315DB Datasheet PDF
280 3300 3 6 315DB Datasheet PDF
300 3300 3 4 315DB Datasheet PDF
300 3300 3 8 355CB Datasheet PDF
315 3300 3 2 315DA Datasheet PDF
315 3300 3 6 355CB Datasheet PDF
315 3300 3 8 355DB* Datasheet PDF
340 3300 3 4 315DB Datasheet PDF
355 3300 3 2 355CA Datasheet PDF
355 3300 3 4 355CB Datasheet PDF
355 3300 3 6 355CB Datasheet PDF
355 3300 3 8 355DB* Datasheet PDF
375 3300 3 8 355DB Datasheet PDF
400 3300 3 2 355CA Datasheet PDF
400 3300 3 4 355CB Datasheet PDF
400 3300 3 6 355DB* Datasheet PDF
400 3300 3 8 400CB Datasheet PDF
425 3300 3 6 355DB* Datasheet PDF
450 3300 3 2 355CA Datasheet PDF
450 3300 3 4 355CB Datasheet PDF
450 3300 3 8 400DB* Datasheet PDF
475 3300 3 4 355DB* Datasheet PDF
475 3300 3 6 400CB Datasheet PDF
500 3300 3 2 355DA* Datasheet PDF
500 3300 3 4 355DB* Datasheet PDF
500 3300 3 6 400DB* Datasheet PDF
500 3300 3 8 400DB* Datasheet PDF
530 3300 3 2 400DA* Datasheet PDF
530 3300 3 8 450CB Datasheet PDF
560 3300 3 4 400CB Datasheet PDF
560 3300 3 6 400DB* Datasheet PDF
600 3300 3 2 400DA* Datasheet PDF
600 3300 3 6 400DB* Datasheet PDF
600 3300 3 8 450CB Datasheet PDF
630 3300 3 4 400CB Datasheet PDF
630 3300 3 6 450CB Datasheet PDF
650 3300 3 2 400DA* Datasheet PDF
650 3300 3 4 400DB* Datasheet PDF
650 3300 3 8 450DB* Datasheet PDF
670 3300 3 6 450CB Datasheet PDF
710 3300 3 2 400DA* Datasheet PDF
710 3300 3 4 400DB* Datasheet PDF
710 3300 3 8 450DB* Datasheet PDF
750 3300 3 2 450DA*-R Datasheet PDF
750 3300 3 4 400DB* Datasheet PDF
750 3300 3 6 450CB Datasheet PDF
800 3300 3 2 450DA*-R Datasheet PDF
800 3300 3 4 400DB* Datasheet PDF
800 3300 3 6 450CB Datasheet PDF
800 3300 3 8 500CB Datasheet PDF
850 3300 3 4 450CB Datasheet PDF
850 3300 3 6 450DB* Datasheet PDF
850 3300 3 8 500CB Datasheet PDF
900 3300 3 2 450DA*-R Datasheet PDF
900 3300 3 4 450CB Datasheet PDF
900 3300 3 6 500CB Datasheet PDF
930 3300 3 2 450DA*-R Datasheet PDF
930 3300 3 4 450DB* Datasheet PDF
930 3300 3 6 500CB Datasheet PDF
930 3300 3 8 500CB Datasheet PDF
1000 3300 3 2 450DA*-R Datasheet PDF
1000 3300 3 4 450DB* Datasheet PDF
1000 3300 3 6 500CB Datasheet PDF
1000 3300 3 8 500DB* Datasheet PDF
Book a Consultation
Have questions or need assistance? Reach out to us through the contact form, and we’ll be happy to assist you.
This field is for validation purposes and should be left unchanged.